Search results for "Power measurement"
showing 10 items of 33 documents
An Improved Load Flow Method for MV Networks Based on LV Load Measurements and Estimations
2019
A novel measurement approach for power-flow analysis in medium-voltage (MV) networks, based on load power measurements at low-voltage level in each secondary substation (SS) and only one voltage measurement at the MV level at primary substation busbars, was proposed by the authors in previous works. In this paper, the method is improved to cover the case of temporary unavailability of load power measurements in some SSs. In particular, a new load power estimation method based on artificial neural networks (ANNs) is proposed. The method uses historical data to train the ANNs and the real-time available measurements to obtain the load estimations. The load-flow algorithm is applied with the e…
DAQs-based wattmeters for high accuracy measurements. Comparison with the Italian power primary standard
2013
Abstract This paper is focused on the use of data acquisition boards (DAQs) for the development of high accuracy PC-based instruments for the measurements of electrical power. The proposed systems are simple, portable and low cost because they are based on commercial data acquisition boards (DAQs) connected to a common personal computer. Data processing is carried out by a commercial software based on an interpolating windowed FFT. In the paper it is shown how the voltage can be sensed directly, thanks to the DAQ input range, thus avoiding expensive voltage dividers. The set up of the DAQs-based solutions is described and the evaluation of their metrological features is made by means of a c…
Real-Time Power Flow Monitoring and Control System for Microgrids Integration in Islanded Scenarios
2019
This article presents an enhanced system for real-time power flow monitoring and control (PFMC) for microgrids integration in medium-voltage (MV) distribution networks. The developed solution includes both system architecture and the monitoring and control algorithms, and it has low implementation and installation costs. It is based on the use of hardware and software solutions previously proposed by the authors, i.e., a distributed measurement, a control and communication architecture, and a supervisory control and data acquisition (SCADA) software, which have been enhanced and integrated for the considered application. The SCADA implements a load flow (LF) algorithm for real-time power fl…
Measurement of Simplified Single- And Three-Phase Parameters for Harmonic Emission Assessment Based on IEEE 1459-2010
2021
This article investigates the feasibility of using a simplified approach, based on the measurement of power ratio parameters, for harmonic emissions assessment at the point of common coupling (PCC). The proposed approach comes from the common concept of power factor correction and the definitions of the IEEE Std. 1459-2010, where line utilization and harmonic pollution levels are evaluated by means of ratios between the power quantities of the apparent power decomposition. In addition to the IEEE Std. 1459–2010 indicators, in this article, the behavior is studied of additional parameters that are conceptually similar to those defined by the IEEE Std. 1459-2010. The suitability of such param…
Uncertainty evaluation in power measurements with commercial data acquisition boards
2011
The paper deals with the metrological characterization of a digital wattmeter developed by using a personal computer, a shunt, two commercial data acquisition boards and commercial software. The uncertainty of the active power measurements is assessed individually characterizing the voltage channel, the current channel and the phase displacement measurement between the two channels. In particular, the uncertainty on the voltage and current rms measurements is evaluated by using an already proposed approach based on the Monte Carlo method and on the usage of five parameters, while the uncertainty on the phase angle is experimentally estimated. In order to validate the proposed approach for t…
LV Measurement Device Placement for Load Flow Analysis in MV Smart Grids
2016
This paper deals with the issue of measurement device placement for load flow analysis in medium-voltage (MV) distribution networks. The study is carried out using an innovative measurement algorithm for load flow analysis developed by the authors. It is based on low-voltage (LV) load power measurements applied on a backward/forward algorithm for the load flow resolution. The final aim is to identify the most suitable number and placement of the LV measurement points in order to limit the uncertainty on the power flow estimation to a target value. The proposed approach is based on the uncertainty evaluation of the estimated power flows; a sensitivity analysis is performed in order to assess…
Uncertainty evaluation in the measurements for the electric power quality analysis
2013
The paper deals with the uncertainty estimation in the measurements performed to assess the electric power quality. In a first steps, according to the 'ISO - Guide to Expression of the Uncertainty in Measurements' all the error sources, which give a significant contribution to the combined uncertainty associated to the measurement results, are identified. Successively, in order to analyze how the errors propagate through the measurement chain, a Monte Carlo based approach is proposed. The method exploits an ad-hoc developed simulator of the measurement process, which takes into account the particular way of propagation of all the identified error sources. Eventually, with the aim of validat…
Electric Power Quality Evaluation in the Presence of Electromagnetic Emissions
2013
The measurements for the assessment of the electric power quality are often carried out in hostile electromagnetic environments. The aim of the paper is analyzing if and how both radiated and conducted electromagnetic emissions can disturb the measurement system used to quantify these disturbances. To achieve the target, an experimental approach is proposed, which, by means of a simple and fast test, allows establishing if the real electromagnetic environment, where power quality analysis is performed, can alter the measurements. © 2013 IEEE.
A PC-based wattmeter for high accuracy power measurements
2010
This paper proposes the use of a commercial data acquisition board (DAQ) connected to a common personal computer for high accuracy power measurements. In the paper the set up of the PC-based wattmeter is described and an experimental evaluation of its metrological performances is made by means of the comparison with a simultaneous coherent digital sampling wattmeter realized with two high-precision DMMs Hewlett Packard Model 3458 A. In both cases the power source is a Fluke 6100A/E electrical power standard. © 2010 IEEE.
A DAQ-based sampling wattmeter for IEEE Std. 1459-2010 powers measurements. Uncertainty evaluation in nonsinusoidal conditions
2015
Abstract This paper presents the evaluation of the metrological performances of a DAQ-based sampling wattmeter (DAQ-SW) for the measurement of IEEE Std. 1459-2010 power quantities in non-sinusoidal conditions. The instrument makes use of two commercial data acquisition (DAQ) boards, a non-inductive current shunt, a personal computer and a commercial software for data processing. Starting from the results of an experimental characterization of the two instrument channels with non-sinusoidal voltages and currents and a correlation analysis, the combined standard uncertainties of IEEE Std. 1459-2010 quantities are evaluated, following the approach of the ISO Guide to the Expression of Uncertai…